PART NUMBER / VULCAN HART
00-358516-00001Vulcan Hart 00-358516-00001 Blower Motor
This part is out of stock right now, so it cannot be added to the cart.
The Vulcan Hart 00-358516-00001 is a blower motor used in commercial kitchen and heating equipment. It turns the blower wheel or fan to circulate air through the unit.
When this motor fails, air stops moving, which can cause poor heating, uneven temperatures, or system shutdowns. Replacing a worn motor restores proper airflow.
Turn off the power at the main breaker before touching any wires or removing panels, then test with a meter to verify power is completely off. If the motor circuit uses a capacitor, discharge it with an insulated tool before touching the terminals, as it can hold a charge even when the power is off. If your equipment uses gas and you smell gas, do not touch any switch. Leave the building immediately and call your gas supplier from outside.
Specifications
| Part number | 00-358516-00001 |
|---|---|
| Brand | Vulcan Hart |
| Part type | Blower motor |
| Frequency | 50/60HZ |
| Height | 10.40 in |
| Length | 11.00 in |
| Voltage | 115V |
| Width | 15.95 in |
From the maker's and parts sellers' listings for this number. Compare with the label on your old part.
What the Blower Motor Does
A blower motor converts electrical energy into mechanical rotation to drive a fan or blower assembly. This movement pushes warm air across the cabinet or draws exhaust through the unit.
Without steady airflow, heat builds up around internal components. Safety limit switches may trip to protect the unit from overheating until the airflow is restored.
Understanding the Specs
Every replacement motor must match the electrical supply and physical space of the original unit. Mismatched voltages or sizes will prevent the part from working safely.
- Voltage: 115V. This part runs on standard 115-volt line power.
- Frequency: 50/60HZ. It is rated to operate on both 50 Hz and 60 Hz electrical systems.
- Length: 11.00 in.
- Width: 15.95 in.
- Height: 10.40 in.
Signs of Failure and Replacement Steps
A failing blower motor often makes unusual grinding noises, hums without turning, or stops running entirely. If the motor hums but will not spin, make sure to check any connected capacitor first, as a weak capacitor can prevent a good motor from starting.
- Shut off electrical power at the breaker panel and confirm the circuit is dead using a voltage tester.
- Access the blower compartment and safely discharge any capacitor connected to the motor circuit using an insulated tool.
- Take a clear photo of every wire connection so you have an exact reference for reassembly.
- Disconnect the wiring harness and remove the mounting bolts holding the motor in place.
- Carefully remove the old motor and slide the replacement into the mounting bracket.
- Reconnect the wires one at a time to the matching terminals, referring to your photo.
- Secure all panels, restore electrical power, and test the equipment for steady airflow.
Read your old part
- Locate the metal data plate or printed label on the side of your old motor housing.
- Wipe away grease or dust to clearly read the part number printed on the label.
- Check that the part number matches 00-358516-00001 exactly.
- Verify the electrical rating on the old label shows 115V and 50/60HZ.
- Measure the physical clearance in your cabinet to confirm the 11.00 in length, 15.95 in width, and 10.40 in height will fit the bracket.
When to call a pro
Hire a licensed technician or electrician if you are unsure how to test line voltage, discharge a capacitor safely, or access the blower housing.
Questions
What voltage does the 00-358516-00001 blower motor require?
This motor is rated for 115V power. It also supports both 50/60HZ line frequencies. Always confirm your power supply matches this rating before connecting wires.
What are the dimensions of this blower motor?
The motor measures 11.00 in in length, 15.95 in in width, and 10.40 in in height. Comparing these measurements to your mounting bracket helps ensure a proper physical fit.
Why does my blower motor hum without spinning?
A fan or motor that hums but will not spin is often caused by a bad capacitor rather than a failed motor. If the capacitor is weak or faulty, the motor cannot generate the torque needed to start rotating.
How can I confirm this motor matches my equipment?
Match the part number directly from the label on your old part. Check that it reads 00-358516-00001, or check the appliance model documentation to verify compatibility.
Related part numbers
- 2U-1200200Fan Motor, APW WyottSame part type
- WR50102Motor Reference Guide, ClevelandSame part type
- 00-411690-00002Timer, Vulcan HartSame brand
- 00-844133-00001Combination Gas Valve, Vulcan HartSame brand
- 2U-1211700Gear Motor, APW WyottSame part type
- VMP00172Shaver Motor Guide, DelfieldSame part type
- 00-770085-00002Valve Reference, Vulcan HartSame brand
- 3-3-01-01-006Gear Motor, Spaceman USASame part type
Browse: Appliance motors by part number
Refrigerator parts and water filters · All part numbers · Superseded part number lookup · How to find a replacement part · Part finder
Brand names and part numbers identify the part and show fit. FindPart is not affiliated with, authorized by, or endorsed by any equipment maker. If you are not sure a repair is safe for you, call a licensed technician.