The Newco 102580 is a tank heater and element. It warms and maintains water temperature inside the equipment tank.

When your unit stops heating properly, the heating element may be worn out. Replacing it restores the heat needed for normal operation.

Turn off power at the breaker and test for power before touching any wires or electrical components. Shut off the water supply to the equipment and empty the tank before removing a tank heating element. Take a photo of every wire before removing a part, then move wires one at a time to the same spots on the new part.

Specifications

Part number102580
BrandNewco
Part typeTank heater/element
Height5.2 in / 13.21 cm
Length8.3 in / 21.08 cm
Voltage120 Volt
Wattage1400 Watt
Width5.75 in / 14.61 cm

From the maker's and parts sellers' listings for this number. Compare with the label on your old part.

What the Tank Heater Element Does

A heating element converts electrical energy into heat to warm liquid inside a holding tank. When power flows to the element terminals, the internal resistance creates heat that spreads directly into the surrounding water.

If the element burns out, the liquid in the tank stays cold or fails to reach the right temperature. Replacing a damaged element helps the unit heat water again.

Understanding the 102580 Specifications

Electrical heating elements must match the voltage and power requirements of the system. Installing an element with mismatched electrical ratings can cause weak heating or electrical damage.

Physical measurements are also important so the element fits properly inside the tank opening without touching the walls.

  • Voltage: 120 Volt
  • Wattage: 1400 Watt
  • Height: 5.2 in / 13.21 cm
  • Length: 8.3 in / 21.08 cm
  • Width: 5.75 in / 14.61 cm

How to Confirm a Replacement Matches

Before choosing a replacement, always verify the numbers on your existing part. Match the part number on the old part, or check the appliance model it is listed for.

Because sizes and ratings differ between machines, never guess on fit. Review the stamped numbers on your old heating element or look up your unit parts manual to ensure 102580 is the correct match.

Signs of Failure and Safe Replacement

A failed tank heater often shows clear warning signs. The water in the tank may remain completely cold, take much longer to heat, or trip the breaker when the unit turns on. Physical damage like cracks, heavy mineral buildup, or burnt terminals also indicates it is time for a replacement.

Always shut off electrical power at the breaker panel and test for power before you begin. Shut off the water supply and drain the tank completely so water does not leak into electrical compartments during removal. Take clear photos of all wiring connections so you can reconnect every wire to the proper terminal on the new element.

Read your old part

  1. Locate the identification stamp or printed label on your old heating element flange or terminal block.
  2. Clean off any dust or residue to read the stamped part number clearly.
  3. Confirm the part number on your old part reads 102580.
  4. Verify that the electrical ratings stamped on the part match 120 Volt and 1400 Watt.

When to call a pro

Working around water and electricity can be dangerous. If you are not comfortable testing for power, draining the tank, or reconnecting wiring, stop work. Hire a licensed technician or electrician for any step you are not sure you can do safely.

Questions

What is the voltage and wattage of the Newco 102580?

The Newco 102580 is rated for 120 Volt and 1400 Watt. Always confirm that your equipment power supply matches these electrical ratings.

What are the dimensions of this heating element?

This element measures 5.2 in / 13.21 cm in height, 8.3 in / 21.08 cm in length, and 5.75 in / 14.61 cm in width.

How do I make sure this part fits my unit?

Match the part number on the old part, or the appliance model it is listed for. Look for 102580 stamped directly on your existing element or listed in your unit documentation.

Do I need to turn off the power before replacing a tank heater?

Yes. Turn off power at the breaker and test for power before touching anything. You should also shut off the water supply and drain the tank before removing the old element.

Related part numbers

  • 202027Tank Element, NewcoSame brand and type
  • 85633Heating Element, APW WyottSame part type
  • 102820Solenoid Valve, NewcoSame brand
  • 100255Solenoid Valve, NewcoSame brand
  • 300705Heating Element, ClevelandSame part type
  • 85632Heating Element Reference, APW WyottSame part type
  • 110958Relay, NewcoSame brand
  • 100250Solenoid Valve, NewcoSame brand

Browse: Newco part numbers · Heating elements by part number

Dryer parts · All part numbers · Superseded part number lookup · How to find a replacement part · Part finder

Brand names and part numbers identify the part and show fit. FindPart is not affiliated with, authorized by, or endorsed by any equipment maker. If you are not sure a repair is safe for you, call a licensed technician.