PART NUMBER / ULTRAFRYER

18-179Ultrafryer 18-179 Ignition Module

Stock
Out of stock
Part type
Ignition module

This part is out of stock right now, so it cannot be added to the cart.

One email when it is back in stock. Nothing else. Privacy policy
Add to quote list

The Ultrafryer 18-179 is an ignition module control board used in commercial fryers. It controls the startup sequence, opening the gas flow and creating the spark or heat needed to light the burner.

If you are holding an old module with this part number, it manages the safety checks and timing for the burner ignition cycle. A functioning ignition module ensures the burner lights reliably when the system calls for heat.

Turn off electrical power at the circuit breaker and test for power before touching any wiring or internal components. If you smell gas at any time, do not touch any electrical switch. Leave the building immediately and call your gas company from outside. Never bypass any safety switch or safety control device during testing or installation.

Specifications

Part number18-179
BrandUltrafryer
Part typeIgnition module
Frequency60HZ
Height2.7 in / 6.86 cm
Length8.75 in / 22.23 cm
Voltage24V
Width7.6 in / 19.30 cm

From the maker's and parts sellers' listings for this number. Compare with the label on your old part.

What the Ignition Module Does

An ignition module acts as the brain for the burner lighting process. When the equipment calls for heat, the module sends power to open the gas supply and activates the ignition source to light the burner.

It also monitors the flame once lighting occurs. If the burner fails to light within a safe time, the module closes the gas supply to prevent unburned fuel from collecting inside the appliance.

Understanding the Part Specifications

The 18-179 ignition module has specific electrical ratings and physical measurements that must match your equipment setup:

Check these measurements against the space available in your equipment housing to ensure the module mounts correctly.

  • Voltage: 24V
  • Frequency: 60HZ
  • Length: 8.75 in / 22.23 cm
  • Width: 7.6 in / 19.30 cm
  • Height: 2.7 in / 6.86 cm

How to Confirm a Match

Control boards must match the exact requirements of your appliance. Confirming the part number on your existing unit prevents electrical issues and ensures proper operation.

The 18-179 module is superseded by part number ULTR18179. If your old part shows either number, they are linked in the part records.

Signs of Failure and Safe Replacement

A failing ignition module often causes the burner to fail to light entirely. It may also try to ignite but stop before a flame is established, or repeatedly lock out during normal operation.

When replacing the module, keep safety as your top priority. Follow a clear step-by-step process to ensure the wiring is transferred correctly without errors.

  1. Turn off electrical power to the unit at the breaker box.
  2. Verify the power is fully off using an electrical test meter.
  3. Take a clear photo of every wire connected to the old module for reference.
  4. Remove the mounting hardware holding the old module in place.
  5. Transfer the wires one at a time to the matching terminals on the replacement unit.
  6. Secure the module in the mounting location, close the access panel, and restore power.

Read your old part

  1. Locate the printed label or stamping on the body of your existing ignition module.
  2. Look for part number 18-179 or superseded number ULTR18179 on the tag.
  3. Check that the electrical rating on the label reads 24V and 60HZ.
  4. Measure the old part to confirm it matches the length of 8.75 in / 22.23 cm, width of 7.6 in / 19.30 cm, and height of 2.7 in / 6.86 cm.
  5. Check the appliance manual to verify that 18-179 is the listed part number for your specific machine.

When to call a pro

Working with gas appliances carries real risks. If you smell gas, need to adjust gas lines or valves, or feel uncertain about electrical testing and wiring, stop immediately and hire a licensed professional technician.

Questions

What voltage does the Ultrafryer 18-179 ignition module require?

This module operates on 24V at a frequency of 60HZ. It is designed to work with low-voltage control circuits.

What part number supersedes the 18-179 module?

Part number 18-179 is superseded by number ULTR18179. Checking for either number on your old part helps ensure a proper match.

What are the dimensions of the 18-179 ignition module?

The module measures 8.75 in / 22.23 cm in length, 7.6 in / 19.30 cm in width, and 2.7 in / 6.86 cm in height.

What safety step should I take before removing the old module?

Always turn off power at the breaker and test for live electricity before touching any wires. It is also wise to take a photo of all connections so you can transfer wires one at a time.

Related part numbers

  • 1051-00011-00Control Board, FetcoSame part type
  • 00-475811Control Board Service Kit, HobartSame part type
  • 18A012Heating Element, UltrafryerSame brand
  • 17A027Motor Reference Guide, UltrafryerSame brand
  • 16921Ignition Module Guide, NiecoSame part type
  • 70458601PLaundry Ignition Control Module, Speed QueenSame part type
  • 18A015Heating Element, UltrafryerSame brand
  • 17A018Pump Motor, UltrafryerSame brand

Browse: Ultrafryer part numbers · Appliance control boards by part number

Refrigerator parts and water filters · All part numbers · Superseded part number lookup · How to find a replacement part · Part finder

Brand names and part numbers identify the part and show fit. FindPart is not affiliated with, authorized by, or endorsed by any equipment maker. If you are not sure a repair is safe for you, call a licensed technician.