PART NUMBER / GAYLORD

18979Gaylord 18979 Damper Actuator

Stock
Out of stock
Part type
Damper actuator

This part is out of stock right now, so it cannot be added to the cart.

One email when it is back in stock. Nothing else. Privacy policy
Add to quote list

The Gaylord 18979 is a damper actuator. A damper actuator uses an electric motor to open and close internal air dampers in your equipment. This movement controls the flow of air through the system when it receives a signal.

If you are holding an old part with the number 18979, this guide will help you understand its physical measurements, electrical requirements, and how to verify a match before installing a replacement.

Turn off all power to the equipment at the breaker before servicing electrical components. Test for power with a meter to verify the circuit is completely dead before touching any wiring. Take a photo of every wire before removing the old part so you can reconnect everything correctly.

Specifications

Part number18979
BrandGaylord
Part typeDamper actuator
Height4.35 in / 11.05 cm
Length12.1 in / 30.73 cm
Voltage24V
Width6.65 in / 16.89 cm

From the maker's and parts sellers' listings for this number. Compare with the label on your old part.

What a Damper Actuator Does

A damper actuator is a motorized device designed to position a mechanical blade or damper. When the system calls for airflow, the actuator turns the shaft to open the passage. Once the cycle finishes or airflow needs to be restricted, it moves the damper back to its set resting position.

If the actuator fails, the damper can become stuck in an open or closed position. This stops proper air movement and can cause the system to perform poorly.

Understanding the 18979 Specs

Every replacement actuator must match the physical footprint and power supply of the original part. The Gaylord 18979 lists several exact physical dimensions and electrical requirements:

Always compare these numbers directly against your existing hardware to ensure it fits in the mounting location.

  • Voltage: 24V
  • Height: 4.35 in / 11.05 cm
  • Length: 12.1 in / 30.73 cm
  • Width: 6.65 in / 16.89 cm

How to Tell if an Actuator Has Failed

A failing damper actuator often gives warning signs before stopping completely. You may hear humming or clicking sounds if internal gears slip while the motor tries to turn. In other cases, the motor may make no sound at all and fail to rotate the shaft when the control system calls for it.

A damper that stays permanently open or closed usually indicates that the actuator motor has burned out or lost its electrical connection. Inspecting the component visually can reveal mechanical binding or loose wiring.

How to Replace the Actuator Safely

Replacing an actuator involves working around electrical wiring and moving mechanical linkages. Follow these steps to complete the replacement safely:

  1. Shut off electrical power to the unit at the main breaker panel.
  2. Test the wires leading to the actuator with a voltage tester to ensure power is off.
  3. Take a clear photo of all wire connections and mounting brackets for reference.
  4. Disconnect the wiring connections and loosen the mounting hardware holding the actuator to the damper shaft.
  5. Remove the old actuator and set the new unit into the exact same position.
  6. Secure the mounting fasteners, reconnect the wires one at a time to the matching terminals, and restore power to test operation.

Read your old part

  1. Locate the identification label on the body of your current actuator.
  2. Wipe away any dust or grease so the numbers are clear to read.
  3. Check that the part number printed on the old label reads 18979.
  4. Verify that the voltage listed on your old part reads 24V.
  5. Measure the old part to confirm its dimensions match 4.35 in / 11.05 cm high, 12.1 in / 30.73 cm long, and 6.65 in / 16.89 cm wide.

When to call a pro

Hire a licensed HVAC technician or electrician for any step you are not sure you can do safely. If you are uncomfortable working with electrical wiring or mounting mechanical linkages, call a licensed professional to handle the replacement.

Questions

What voltage does the Gaylord 18979 actuator require?

The Gaylord 18979 runs on 24V. Most home thermostats, contactor coils, and control boards supply a 24 V control signal from a transformer.

What are the dimensions of the 18979 damper actuator?

The 18979 measures 4.35 in / 11.05 cm in height, 12.1 in / 30.73 cm in length, and 6.65 in / 16.89 cm in width. Make sure your mounting bracket has enough clearance for these measurements.

How do I match this part to my old actuator?

Match the part number on the old part, or check the appliance model it is listed for. Look for 18979 on the maker label of your old unit.

What should I do before disconnecting the wires on the old part?

Always turn off the breaker and verify the power is off with a meter. Then, take a photo of every wire before removing the old part so you can move wires one at a time to the same spots.

Related part numbers

  • 10156Coil Reference and Fit Guide, GaylordSame brand and type
  • 27592Timer Reference, NiecoSame part type
  • 10120Light Housing, GaylordSame brand
  • 18863Power Supply Board, GaylordSame brand
  • 034934Heater Drain Pan, NorlakeSame part type
  • 4071-PTemperature Control Reference, NiecoSame part type
  • 12713Solenoid Repair Kit, GaylordSame brand
  • 37927PLaundry Part, Speed QueenSame part type

Browse: Gaylord part numbers

Refrigerator parts and water filters · All part numbers · Superseded part number lookup · How to find a replacement part · Part finder

Brand names and part numbers identify the part and show fit. FindPart is not affiliated with, authorized by, or endorsed by any equipment maker. If you are not sure a repair is safe for you, call a licensed technician.