PART NUMBER / ULTRAFRYER
18A021Ultrafryer 18A021 Momentary Switch Reference Guide
This part is out of stock right now, so it cannot be added to the cart.
The Ultrafryer 18A021 is a momentary switch used in commercial cooking equipment. A momentary switch engages an electrical circuit only while pressed. Once released, internal spring pressure returns the switch to its resting state.
This switch handles control signals or specific short-duration tasks inside your Ultrafryer unit. If the button sticks, feels loose, or fails to complete the circuit when pressed, your equipment may stop responding as expected.
Turn off the power at the breaker panel and test for power before touching any wiring or opening equipment panels. If your equipment uses gas and you smell gas, do not touch any switch. Leave the building immediately and call your gas company from outside. Take a clear photo of all wiring connections before you disconnect the old switch.
Specifications
| Part number | 18A021 |
|---|---|
| Brand | Ultrafryer |
| Part type | Momentary switch |
| Height | 0.65 in / 1.65 cm |
| Length | 2 in / 5.08 cm |
| Voltage | 120V |
| Width | 0.65 in / 1.65 cm |
From the maker's and parts sellers' listings for this number. Compare with the label on your old part.
What the Ultrafryer 18A021 Does
A momentary switch acts as a temporary trigger inside your equipment. Unlike a standard toggle switch that clicks and stays in an on or off position, a momentary switch only changes state while you hold it down. Releasing your finger opens or closes the contacts back to their normal resting position.
Because of this action, momentary switches are often used for reset functions, fill controls, or menu selection tasks. When internal contacts wear out or get coated with grease and debris, the electrical signal will not pass through even if the button physically depresses.
Understanding the 18A021 Specifications
Replacing an electrical switch requires matching both the electrical rating and the physical size so it seats properly in the panel cutout. The Ultrafryer 18A021 has specific ratings and measurements you can check against your old part.
- Voltage: 120V
- Length: 2 in / 5.08 cm
- Width: 0.65 in / 1.65 cm
- Height: 0.65 in / 1.65 cm
Signs of Switch Failure and Safe Replacement
A failing momentary switch often shows physical or electrical symptoms. The push mechanism might stick down instead of popping back up. In other cases, the button clicks normally, but internal contact corrosion stops the 120V circuit from closing. You can replace the switch by following basic electrical safety practices.
- Turn off power to the unit at the circuit breaker and test the circuit with a meter to verify no voltage is present.
- Access the rear of the control panel to view the switch body and connected wires.
- Take a photo of every wire connected to the switch terminals to record proper placement.
- Depress any mounting tabs or remove retaining nuts holding the switch body in the panel.
- Move wires one at a time from the old switch to the exact same spots on the new part.
- Snap or fasten the switch into the panel, restore power at the breaker, and test operation.
Read your old part
- Turn off power and inspect the exterior housing or stamp on your existing switch.
- Look for the stamped part number 18A021 directly on the switch body.
- Check that the voltage rating reads 120V to ensure electrical compatibility.
- Measure the old switch body to confirm the length is 2 in / 5.08 cm, width is 0.65 in / 1.65 cm, and height is 0.65 in / 1.65 cm.
- Match the part number on the old part, or the appliance model it is listed for in your equipment manual.
When to call a pro
If you are uncomfortable testing live voltage, if the wiring looks burnt or damaged, or if replacing the switch does not restore normal operation, stop and call a licensed technician or electrician to diagnose the issue.
Questions
What is the voltage rating for the Ultrafryer 18A021 switch?
The switch is rated for 120V operation. Always verify that your equipment control circuit operates at this same voltage before installing a replacement.
What are the physical dimensions of the 18A021 momentary switch?
The switch measures 2 in / 5.08 cm in length, 0.65 in / 1.65 cm in width, and 0.65 in / 1.65 cm in height. Checking these dimensions helps ensure it fits your existing panel cutout.
How does a momentary switch differ from a standard rocker or toggle switch?
A momentary switch only maintains its contact while someone actively presses the button. A standard switch stays latched in the on or off position until manually moved again.
What should I do before disconnecting wires from the old switch?
Turn off power at the breaker and test for power to confirm the unit is safe to touch. Always take a clear photo of the wire connections before unplugging anything so you can move wires one at a time to the matching terminals.
Related part numbers
- 18A081Toggle Switch, UltrafryerSame brand and type
- 18A287Toggle Switch, UltrafryerSame brand and type
- 2T-70716Hi Limit Thermostat, BloomfieldSame part type
- 18A047Transformer with wires, UltrafryerSame brand
- 18A015Heating Element, UltrafryerSame brand
- 2J-87053-EGOInfinite Control Guide, APW WyottSame part type
- 18A012Heating Element, UltrafryerSame brand
- 324-36989-00Freezer Thermostat, TraulsenSame part type
Browse: Ultrafryer part numbers · Switches, sensors and thermostats by part number
Refrigerator parts and water filters · All part numbers · Superseded part number lookup · How to find a replacement part · Part finder