PART NUMBER / ULTRAFRYER
18A100Ultrafryer 18A100 Contactor
This part is out of stock right now, so it cannot be added to the cart.
The Ultrafryer 18A100 is an electrical contactor used in commercial appliance equipment. It acts as an electrically controlled switch that opens and closes high-power circuits.
When a low-voltage control signal reaches the contactor coil, an internal magnetic field pulls the contacts closed. This connects power to the heavy electrical loads inside the unit, allowing heating elements or other components to run.
Turn off electrical power at the main breaker before touching any wiring or opening panels. A contactor carries high voltage that can kill. Test for power with a reliable meter to make sure the circuit is completely dead before servicing. Hire a licensed technician or electrician for any step you are not sure you can perform safely.
Specifications
| Part number | 18A100 |
|---|---|
| Brand | Ultrafryer |
| Part type | Contactor |
| Amps | 60A |
| Frequency | 50/60HZ |
| Height | 1.85 in / 4.70 cm |
| Length | 11.8 in / 29.97 cm |
| Poles | 3 |
| Voltage | 24V |
| Width | 7.6 in / 19.30 cm |
From the maker's and parts sellers' listings for this number. Compare with the label on your old part.
Match these numbers
- 01Poles: same count, 1 or 2
- 02Coil volts: must be the same, most homes use 24 V
- 03Amps: same or higher than your old one
What the Ultrafryer 18A100 Does
In commercial appliances, high-current electrical loads cannot be safely wired directly through delicate control boards or thermostats. Instead, the unit uses a contactor like the Ultrafryer 18A100 to bridge the two sides.
A low-voltage signal energizes the coil inside the contactor. This pulls a set of internal contacts together, completing the circuit for the heavy electrical line. When the control signal ends, a spring pushes the contacts apart to shut off power.
Understanding the Part Specifications
Every contactor has ratings that must match the circuit it protects. The 18A100 has specific electrical and physical measurements listed on its label.
- Voltage: 24V. This is the voltage needed to energize the contactor coil.
- Frequency: 50/60HZ. The coil operates on standard 50 or 60 hertz alternating current.
- Amps: 60A. The main contacts can carry up to 60 amperes of current.
- Poles: 3. The contactor controls three separate electrical lines simultaneously.
- Length: 11.8 in / 29.97 cm.
- Width: 7.6 in / 19.30 cm.
- Height: 1.85 in / 4.70 cm.
Signs of Contactor Failure and Safe Replacement
Contactors cycle frequently during normal operation. Over time, the contacts can pit, burn, or weld shut. A failing contactor coil may hum loudly, chatter, or fail to pull in when voltage is applied.
If the contacts weld shut, connected equipment may continue running even when turned off. If the contacts burn out completely, the equipment will not heat or turn on. Follow safe installation procedures when replacing a worn contactor.
- Shut off power at the main electrical breaker panel.
- Test all incoming and outgoing connections with a voltage meter to confirm no power is present.
- Take a photo of every wire before removing the old part. This provides a clear reference for reinstallation.
- Loosen the mounting screws and move wires one at a time to the same spots on the new part.
- Secure the contactor firmly to its mounting plate and check that all terminal screws are tight.
Read your old part
- Turn off power to the equipment and locate the installed contactor.
- Look at the printed label on the face or side of the contactor housing.
- Confirm the part number reads 18A100.
- Check that the coil voltage reads 24V and the frequency indicates 50/60HZ.
- Verify the electrical rating shows 60A with 3 poles.
- Match the part number on the old part, or the appliance model it is listed for.
When to call a pro
Hire a licensed HVAC technician or electrician for any step you are not sure you can do safely. High-voltage commercial electrical components carry serious shock hazards, and a qualified technician has the training to test circuits and wire components correctly.
Questions
What coil voltage does the Ultrafryer 18A100 require?
The Ultrafryer 18A100 operates with a 24V control signal. It is rated for a frequency of 50/60HZ.
How many poles does this contactor have?
This contactor has 3 poles. That means it opens and closes three separate electrical paths at the same time.
What is the amp rating for part 18A100?
The Ultrafryer 18A100 contactor is rated for 60A. Replacing it with a lower amp rating could cause electrical failure.
What are the dimensions of this contactor?
The contactor measures 11.8 in / 29.97 cm in length, 7.6 in / 19.30 cm in width, and 1.85 in / 4.70 cm in height.
Related part numbers
- 18A283Mercury Contactor, UltrafryerSame brand and type
- 22540Contactor, UltrafryerSame brand and type
- 3-1-01-01-010Contactor, Spaceman USASame part type
- 18A081Toggle Switch, UltrafryerSame brand
- 18A402-CContactor, UltrafryerSame part type
- KE603902-6Contactor Reference Guide, ClevelandSame part type
- 18A287Toggle Switch, UltrafryerSame brand
- 18A047Transformer with wires, UltrafryerSame brand
Browse: Ultrafryer part numbers · Contactors by part number · Ultrafryer contactors by part number
AC condenser parts · All part numbers · Superseded part number lookup · How to find a replacement part · Part finder