PART NUMBER / APW WYOTT

30201APW Wyott 30201 Terminal Block

Stock
Out of stock
Part type
Terminal block

This part is out of stock right now, so it cannot be added to the cart.

One email when it is back in stock. Nothing else. Privacy policy
Add to quote list

The APW Wyott 30201 is a terminal block designed for commercial kitchen and appliance equipment. It acts as a central junction point where electrical supply wiring connects securely to internal device circuits.

In your equipment, this block organizes power lines into separate paths. It holds each wire tightly under a secure terminal so electricity flows steadily without loose connections or short circuits.

Turn off electrical power at the main circuit breaker before touching any wiring or opening the equipment panel. Always test the terminal block and surrounding wires with a reliable voltage tester to confirm no electrical current is present. Take a clear photo of all connected wires before loosening any screws so you can restore every wire to its exact location.

Specifications

Part number30201
BrandAPW Wyott
Part typeTerminal block
Amps50A
Height0.8 in / 2.03 cm
Length3.1 in / 7.87 cm
Poles3 Pole
Voltage600V
Width1.75 in / 4.45 cm

From the maker's and parts sellers' listings for this number. Compare with the label on your old part.

What the APW Wyott 30201 Terminal Block Does

A terminal block serves as an insulated connection station inside electrical appliances. Instead of splicing wires together with wire nuts, incoming power feeds attach to one side of the block, and the internal components connect to the other.

The rigid housing keeps wire ends spaced apart safely. This prevents bare conductors from touching each other or the metal frame of the machine.

Understanding the Part Specifications

Electrical blocks are rated for maximum electrical load and physical size. The numbers stamped on the APW Wyott 30201 define the limits it can handle safely in an appliance circuit.

  • Voltage: 600V. This shows the maximum electrical potential the insulated block is built to handle.
  • Amps: 50A. This is the maximum current capacity rated for the terminal connections.
  • Poles: 3 Pole. The block provides three separate, isolated electrical pathways.
  • Length: 3.1 in / 7.87 cm across the mounting base.
  • Width: 1.75 in / 4.45 cm.
  • Height: 0.8 in / 2.03 cm.

Signs of Terminal Block Failure and Safe Replacement

Terminal blocks can fail over time due to heat, vibration, or loose wire screws. A loose connection creates resistance, which leads to heat buildup.

Inspect the block closely. Look for melted plastic, black scorching, cracked screw housings, or loose terminals that will no longer tighten down. If you see physical damage or scorched insulation, the block must be replaced.

  1. Turn off power at the circuit breaker and test for power to confirm the unit is completely de-energized.
  2. Take a photo of every wire showing which terminal screw it connects to.
  3. Loosen the terminal screws and remove the wires one at a time.
  4. Unscrew the mounting hardware holding the damaged terminal block to the chassis and remove it.
  5. Fasten the replacement block in place using the original mounting points.
  6. Move wires one at a time to the same spots on the new block and tighten all terminal screws securely.

Read your old part

  1. Locate the part number stamped directly on the body of your existing terminal block.
  2. Check that the stamped number reads 30201.
  3. Review manufacturer documentation to see if your unit lists part number 30201 or newer superseded number APWP1-30201.
  4. Measure the old part to confirm it matches 3.1 in / 7.87 cm in length, 1.75 in / 4.45 cm in width, and 0.8 in / 2.03 cm in height.
  5. Verify that your existing unit uses a 3 pole layout rated for up to 600V and 50A.

When to call a pro

If you are uncomfortable testing for live voltage, or if the wiring inside your equipment shows extensive heat damage, stop immediately. Disconnects and line voltage wiring carry high electrical current. Hire a licensed electrician or appliance technician for any step you are not sure you can do safely.

Questions

What does a 3 pole terminal block mean?

A 3 pole terminal block provides three separate electrical channels on one shared base. Each channel is insulated from the others to keep three distinct hot, neutral, or supply lines safely divided.

Has the APW Wyott 30201 part number changed?

Yes. Part number 30201 has been superseded by part number APWP1-30201. Both numbers identify this terminal block design.

What are the exact physical dimensions of this block?

The APW Wyott 30201 measures 3.1 in / 7.87 cm in length, 1.75 in / 4.45 cm in width, and 0.8 in / 2.03 cm in height.

Related part numbers

  • 1107203Terminal Block, APW WyottSame brand and type
  • 2E-P1003ATerminal Block, APW WyottSame brand and type
  • 369189Terminal Block, LincolnSame part type
  • 22544Terminal Block Reference, UltrafryerSame part type
  • 54096Heating Element Reference, APW WyottSame brand
  • 2U-1211700Gear Motor, APW WyottSame brand
  • 54114Heating Element, APW WyottSame brand
  • 2U-1200200Fan Motor, APW WyottSame brand

Browse: APW Wyott part numbers · Terminal blocks by part number

Refrigerator parts and water filters · All part numbers · Superseded part number lookup · How to find a replacement part · Part finder

Brand names and part numbers identify the part and show fit. FindPart is not affiliated with, authorized by, or endorsed by any equipment maker. If you are not sure a repair is safe for you, call a licensed technician.