PART NUMBER / CLEVELAND

5018006Cleveland 5018006 Blower Burner

Stock
Out of stock
Part type
Blower burner

This part is out of stock right now, so it cannot be added to the cart.

One email when it is back in stock. Nothing else. Privacy policy
Add to quote list

The Cleveland 5018006 is a blower burner used in commercial cooking and heating equipment. It moves air and supports the burner assembly to keep the combustion process running properly.

If you are holding an old unit with this number, this guide helps you check the physical size, voltage, and identification markings before you begin any service work.

Turn off power at the circuit breaker and test for power before touching any wires. If you smell gas, do not touch any switch. Leave the house or building and call your gas company from outside. Gas valve work means opening gas lines and setting gas pressure. A licensed tech should do it.

Specifications

Part number5018006
BrandCleveland
Part typeBlower burner
Height7.6 in / 19.30 cm
Length12.4 in / 31.50 cm
Voltage110V
Width10.4 in / 26.42 cm

From the maker's and parts sellers' listings for this number. Compare with the label on your old part.

What the Blower Burner Does

A blower burner delivers a steady stream of air into the burner area. This airflow mixes with fuel to maintain a steady, clean flame during operation.

When a blower stops turning, the equipment cannot maintain the proper draft or combustion mix. The heating cycle will stall, or safety controls will prevent the unit from lighting.

Understanding the Part Specifications

Replacing an appliance part requires an exact match on voltage and dimensions so it fits the mounting space and connects safely to the power supply.

The 5018006 part number carries the following stated ratings:

  • Voltage: 110V
  • Height: 7.6 in / 19.30 cm
  • Length: 12.4 in / 31.50 cm
  • Width: 10.4 in / 26.42 cm

Signs of Failure and Safe Replacement

Blower burners often fail when their internal motor wears out, bearings seize, or electrical connections fail. You might hear abnormal humming or grinding noises, or the fan wheel may refuse to turn entirely.

Follow these general steps to replace the part safely once you have confirmed the failure:

  1. Turn off electrical power at the breaker panel and verify there is no live voltage using an electrical tester.
  2. Take a photo of every wire before removing the old part so you have a clear reference.
  3. Disconnect the wiring harness and remove the mounting hardware holding the blower in place.
  4. Position the new blower assembly and secure it using the existing brackets and screws.
  5. Move wires one at a time to the same spots on the new part, checking your photo to ensure each connection matches.
  6. Restore electrical power and test the appliance through a complete heating cycle.

Read your old part

  1. Look directly at the metal housing or data label on your old blower burner.
  2. Check that the part number stamped on the unit reads 5018006.
  3. Verify the voltage rating on the old part matches 110V.
  4. Measure the old unit to confirm the outer dimensions match 7.6 in / 19.30 cm high, 12.4 in / 31.50 cm long, and 10.4 in / 26.42 cm wide.
  5. Match the part number on the old part, or the appliance model it is listed for.

When to call a pro

Hire a licensed HVAC technician or licensed pro for any step you are not sure you can do safely. Working with gas supply lines or unfamiliar electrical wiring requires professional training to prevent hazards.

Questions

What voltage does the Cleveland 5018006 blower burner use?

This blower burner operates on 110V. Always confirm your equipment supply voltage matches this rating before connecting any wires.

What should I do before disconnecting wires from my old blower?

Take a photo of every wire before removing a part. Move wires one at a time to the same spots on the new part to prevent wiring errors.

What should I do if I smell gas while checking the burner?

If you smell gas, do not touch any switch. Leave the house or building immediately and call your gas company from outside.

How can I be sure this part matches my old blower?

Match the part number on the old part, or the appliance model it is listed for. You can also compare the height, length, and width against the specs of your existing unit.

Related part numbers

  • 5018007Burner Fan, ClevelandSame brand and type
  • 300888Timer Reference Guide, ClevelandSame brand and type
  • 4030432Power Supply Reference, AntunesSame part type
  • 5015020Halogen Bulb, ClevelandSame brand
  • 5018023Auxiliary Fan, ClevelandSame part type
  • 1542002NEMA Cordset, APW WyottSame part type
  • 5005045Range Light Bulb, ClevelandSame brand
  • 5056374Frequency Converter, ClevelandSame part type

Browse: Cleveland part numbers

Refrigerator parts and water filters · All part numbers · Superseded part number lookup · How to find a replacement part · Part finder