PART NUMBER / APW WYOTT
AS-85601APW Wyott AS-85601 Buss Fuse Reference
This part is out of stock right now, so it cannot be added to the cart.
The APW Wyott AS-85601 is a Buss fuse. It acts as an electrical safety component designed to protect internal wiring and circuits from dangerous current overloads.
When an electrical surge or fault draws more current than the circuit can safely handle, the fuse opens. This breaks the circuit to prevent further damage to connected parts.
Turn off power at the breaker and test for power before touching any electrical parts. Never replace a fuse with one of a higher current rating, and never bypass a fuse. Use an insulated tool when removing or installing fuses in a fuse block or holder.
Specifications
| Part number | AS-85601 |
|---|---|
| Brand | APW Wyott |
| Part type | Buss fuse |
| Amps | 3 Amp |
| Height | 0.3 in / 0.76 cm |
| Length | 1.35 in / 3.43 cm |
| Width | 0.35 in / 0.89 cm |
From the maker's and parts sellers' listings for this number. Compare with the label on your old part.
What the Buss Fuse Does
A fuse is designed to be the weakest link in an electrical path. Current flows through an internal metal strip or wire that heats up as power passes through it.
If the current stays within normal limits, the fuse conducts power continuously. If an electrical short or overload occurs, the element melts and opens the circuit, stopping the flow of electricity immediately.
Understanding the AS-85601 Specifications
Fuses must match their specified physical size and electrical ratings exactly. The AS-85601 carries specific ratings provided by the maker:
Using a fuse with the wrong physical dimensions will prevent it from seating properly in the clip or holder, while the wrong rating risks electrical damage.
- Current rating: 3 Amp
- Height: 0.3 in / 0.76 cm
- Length: 1.35 in / 3.43 cm
- Width: 0.35 in / 0.89 cm
How to Confirm a Replacement Matches
To ensure you have the correct replacement, compare the part in your hand with the manufacturer markings.
Match the part number on the old part, or check the documentation for the unit it is listed for. Because this part does not list alternative replacement numbers, the number on the part should match AS-85601 directly.
Signs of a Blown Fuse and Safe Replacement Steps
When a fuse blows, the machine or circuit it protects will stop receiving power completely. You may see a broken link inside the body or dark discoloration, though some blown fuses look completely normal on the outside.
Follow these steps to safely swap the old fuse for a new one:
- Shut off electrical power at the main breaker box.
- Test the equipment with a voltage tester to verify no electrical power is present.
- Take a clear photo of the fuse holder and wire layout before touching anything.
- Carefully extract the old fuse using a fuse puller or insulated hand tool.
- Press the new fuse firmly into the holder clips until it is fully seated.
- Restore power at the breaker and verify normal operation.
Read your old part
- Remove the old fuse and look at the metal end caps or body label.
- Check that the part number reads AS-85601.
- Confirm the current rating stamped on the fuse is 3 Amp.
- Measure the dimensions to ensure they match 1.35 in length, 0.35 in width, and 0.3 in height.
When to call a pro
If a replacement fuse blows immediately after power is restored, stop work right away. A repeated blown fuse points to a direct short or failing component elsewhere in the wiring. Hire a licensed technician or electrician to diagnose the underlying fault safely.
Questions
What is the amp rating of the APW Wyott AS-85601?
The AS-85601 has a rating of 3 Amp. It is designed to open if the current exceeds this threshold.
What are the exact measurements of this fuse?
The fuse measures 1.35 in / 3.43 cm in length, 0.35 in / 0.89 cm in width, and 0.3 in / 0.76 cm in height. These dimensions allow it to seat securely in its designated holder.
Can I replace the AS-85601 with a fuse that has a higher amp rating?
No, you should never install a fuse with a higher rating than specified. Doing so allows excessive current to flow through the wiring, which can cause severe component damage or electrical hazards.
Related part numbers
- 2E-67005Toggle Switch, APW WyottSame brand and type
- 47591400Switch or Sensor Reference, APW WyottSame brand and type
- MER340038Rocker Switch, DelfieldSame part type
- 990092800Switch Upgrade Kit, Hamilton BeachSame part type
- AS-1119522Contactor, APW WyottSame brand
- AS-69148Relay, APW WyottSame brand
- SEP90024Infinite Control Switch, DelfieldSame part type
- 960020801Toggle Switch, Hamilton BeachSame part type
Browse: APW Wyott part numbers · Switches, sensors and thermostats by part number · APW Wyott switches, sensors and thermostats by part number
Refrigerator parts and water filters · All part numbers · Superseded part number lookup · How to find a replacement part · Part finder
Brand names and part numbers identify the part and show fit. FindPart is not affiliated with, authorized by, or endorsed by any equipment maker. If you are not sure a repair is safe for you, call a licensed technician.