The Cleveland ELB00-7500016 is an electric solenoid valve used in commercial steam equipment. Solenoid valves use an electromagnetic coil to open or close an internal valve body, controlling the flow of steam or water through the unit.

When the equipment calls for steam, an electrical signal energizes the coil. This creates a magnetic field that lifts or shifts an internal plunger to allow flow. When the signal stops, the valve shuts to block flow.

Turn off power at the breaker and test for power before touching any wires or electrical components. Shut off the water or steam supply to the appliance before loosening any plumbing connections. Allow the equipment and lines to cool down completely to avoid burns from hot surfaces, steam, or trapped water.

Specifications

Part numberELB00-7500016
BrandCleveland
Part typeSolenoid valve
Frequency50/60HZ
Height3 in / 7.62 cm
Length4.4 in / 11.18 cm
Voltage120V
Width5 in / 12.70 cm

From the maker's and parts sellers' listings for this number. Compare with the label on your old part.

What the Solenoid Valve Does

In steam appliances, a solenoid valve serves as an automated gatekeeper. It opens and closes the inlet line that feeds steam or water into the cooking cavity or generator based on signals from the control system.

If the solenoid coil burns out, the valve may stay shut and prevent the unit from heating or filling. If debris jams the valve seat or the internal spring weakens, the valve may stick open, leading to uncontrolled flow or leaks.

Understanding the Specs

Matching electrical ratings and physical measurements is essential for safe operation and proper fit. Here are the exact specifications for this component:

  • Voltage: 120V
  • Frequency: 50/60HZ
  • Height: 3 in / 7.62 cm
  • Length: 4.4 in / 11.18 cm
  • Width: 5 in / 12.70 cm

Confirming a Proper Match

Before replacing an old valve, inspect the markings on the body and the coil housing. Solenoid valves often look similar across different equipment models, but voltage and port designs vary.

Make sure the label on your existing part explicitly lists ELB00-7500016. Check that the coil is rated for 120V and 50/60HZ. Finally, compare the physical footprint to ensure the 3 in height, 4.4 in length, and 5 in width will clear any nearby brackets or tubing inside the equipment cabinet.

Signs of Failure and Safe Replacement

Common signs of a failed solenoid valve include an appliance that fails to fill with steam, continuous hissing, or water pooling when the unit should be off. A humming coil that does not open the valve can point to a mechanical jam, while a cold coil that receives power but does nothing usually has an open electrical circuit.

  1. Turn off electrical power to the appliance at the breaker panel and verify there is no power present.
  2. Shut off the supply line feeding the valve and release any trapped system pressure.
  3. Take a photo of every wire connection to ensure they return to the correct terminals.
  4. Disconnect the wiring and carefully unthread the valve fittings from the plumbing line.
  5. Install the replacement valve, taking note of any flow direction arrows on the body.
  6. Reconnect the plumbing connections, restore the supply line, and inspect for leaks before restoring power.

Read your old part

  1. Locate the identification tag or stamped text on the old valve coil or metal body.
  2. Check that the part number matches ELB00-7500016.
  3. Verify the electrical rating stamped on the coil matches 120V and 50/60HZ.
  4. Measure the old component to confirm it matches 3 in height, 4.4 in length, and 5 in width.
  5. Confirm your equipment manual or parts list specifies this exact part number.

When to call a pro

Working with commercial steam lines and electrical circuits carries serious risks of burns and electric shock. If you are unsure how to safely disconnect the plumbing, verify power is off, or test the circuit, stop and hire a licensed professional technician.

Questions

What voltage does the ELB00-7500016 solenoid valve use?

This valve is rated for 120V at 50/60HZ. It requires a standard 120V control circuit to energize the coil.

What are the dimensions of this valve?

The valve measures 3 in / 7.62 cm in height, 4.4 in / 11.18 cm in length, and 5 in / 12.70 cm in width.

How do I know if my old part matches this number?

Match the part number printed on your old valve or look up the appliance model it is listed for. Look for ELB00-7500016 on the valve body or coil label.

Related part numbers

  • FK22221Solenoid Drain Valve Kit, ClevelandSame brand and type
  • 5056379Solenoid Valve, ClevelandSame brand and type
  • 3370071022Solenoid Valve, SchaererSame part type
  • FA95074Nylon Anchor Nut, ClevelandSame brand
  • 6056958Firing Device, ClevelandSame brand
  • SP988-8800003Solenoid Coil, ClevelandSame part type
  • 3370064000Solenoid Valve, SchaererSame part type
  • FK08166Element Kit, ClevelandSame brand

Browse: Cleveland part numbers · Solenoid valves and coils by part number · Cleveland solenoid valves and coils by part number

Refrigerator parts and water filters · All part numbers · Superseded part number lookup · How to find a replacement part · Part finder

Brand names and part numbers identify the part and show fit. FindPart is not affiliated with, authorized by, or endorsed by any equipment maker. If you are not sure a repair is safe for you, call a licensed technician.