Add to quote list

This part is a pump associated with the brand Cleveland. A pump moves fluid through your equipment during normal operation.

When a pump wears out, fluid may stop flowing properly. Replacing a faulty pump helps restore the intended operation of the system.

Turn off electrical power at the breaker before inspecting or servicing any electrical components, and test for power before touching anything. If you smell gas at any point, do not touch any switch. Leave the house and call your gas company from outside. Shut off any connected water supply lines before disconnecting plumbing or pump fittings.

Specifications

Part number113231
BrandCleveland
Part typePump
Height5.85 in / 14.86 cm
Length7.5 in / 19.05 cm
Voltage110V
Width7.45 in / 18.92 cm

From the maker's and parts sellers' listings for this number. Compare with the label on your old part.

What the Pump Does

A pump provides the mechanical force needed to move liquids through an appliance or equipment system. It helps circulate or drain water as the cycle requires.

If the pump stops working, fluid can back up or fail to reach where it needs to go. This can cause the equipment to stop running or display an error condition.

Understanding the Specifications

Electrical and physical measurements must match your installation space and wiring. Review the specific dimensions and voltage rating on your old part before installing a replacement.

  • Height: 5.85 in / 14.86 cm
  • Length: 7.5 in / 19.05 cm
  • Width: 7.45 in / 18.92 cm
  • Voltage: 110V

How to Confirm a Match

Matching part numbers is the most reliable way to find the correct replacement. Always inspect the label directly on your existing pump or reference your appliance model records.

Check that the physical size fits the designated mounting area and that the voltage matches the electrical supply specified for the equipment.

Signs of Failure and Safe Replacement

Common signs of pump failure include unusual humming sounds without water moving, visible leaks around the housing, or equipment shutting down due to drainage issues.

Follow these steps to replace the part safely once you have confirmed an exact match.

  1. Turn off electrical power at the breaker panel and test to ensure power is completely off.
  2. Shut off any incoming water supply connected to the unit.
  3. Take a photo of every wire and hose before removing the old part.
  4. Disconnect the wiring connections and fluid lines carefully.
  5. Remove the mounting hardware and pull the old pump out.
  6. Mount the new pump in place and move wires one at a time to the same spots as shown in your photo.
  7. Reconnect the fluid lines securely, turn the water and power back on, and check for leaks.

Read your old part

  1. Locate the manufacturer label on your existing pump housing.
  2. Read the part number stamped or printed on the label.
  3. Check that the label displays part number 113231.
  4. Verify the voltage rating on the old part reads 110V.
  5. Match the appliance model it is listed for if the part number is worn off or unreadable.

When to call a pro

Hire a licensed technician or licensed electrician for any step you are not sure you can do safely, especially when handling line voltage wiring or plumbing lines.

Questions

What voltage does the 113231 pump use?

This pump is rated for 110V. Always confirm your equipment supply voltage matches this specification before installing.

What are the dimensions of the Cleveland 113231 pump?

The pump measures 5.85 in / 14.86 cm in height, 7.5 in / 19.05 cm in length, and 7.45 in / 18.92 cm in width. Make sure the mounting area accommodates these dimensions.

How can I make sure this pump fits my unit?

Match the part number on the old part, or check the appliance model it is listed for. Look for part number 113231 on the label.

What safety steps should I take before removing the old pump?

Turn off the electrical power at the breaker and test for power before touching any wires. Also, shut off the water supply and leave the building immediately to call the gas company if you smell gas.

Related part numbers

  • 5018035Pump Reference Guide, ClevelandSame brand and type
  • 2062336-02SIce Machine Pump Reference, Ice-O-MaticSame part type
  • 10223Detergent Pump Reference, GaylordSame part type
  • 300358Rocker Switch, ClevelandSame brand
  • 41350Buzzer Assembly, ClevelandSame brand
  • 4040144Oscillating Water Pump, AntunesSame part type
  • 10222Detergent Pump, GaylordSame part type
  • 300362-CLESolenoid Valve, ClevelandSame brand

Browse: Cleveland part numbers · Drain pumps by part number

Washer parts · All part numbers · Superseded part number lookup · How to find a replacement part · Part finder

Brand names and part numbers identify the part and show fit. FindPart is not affiliated with, authorized by, or endorsed by any equipment maker. If you are not sure a repair is safe for you, call a licensed technician.