PART NUMBER / CLEVELAND
5018035Cleveland 5018035 Pump Reference Guide
This part is out of stock right now, so it cannot be added to the cart.
The Cleveland 5018035 is a replacement pump. If you are holding an old part with this number, it serves to move liquid through your equipment during operation.
Pumps rely on precise electrical ratings and physical measurements to operate properly inside the cabinet. Reviewing the markings on your existing part helps ensure you choose the correct replacement.
Turn off power at the main breaker before inspecting, testing, or servicing electrical components. Always test the wires and terminals with a meter to verify that the power is fully off before touching anything. Shut off the water supply to the equipment before disconnecting any liquid lines.
Specifications
| Part number | 5018035 |
|---|---|
| Brand | Cleveland |
| Part type | Pump |
| Frequency | 50/60HZ |
| Height | 3.05 in / 7.75 cm |
| Length | 3.9 in / 9.91 cm |
| Width | 6 in / 15.24 cm |
From the maker's and parts sellers' listings for this number. Compare with the label on your old part.
What the Pump Does
A pump creates the necessary flow to move water or other fluids through the appliance. In commercial kitchen and heating equipment, proper circulation is vital for smooth cycles and proper drainage.
When a pump stops running, fluid can back up or stay stagnant. This can stop the equipment from completing its cycle or cause error states.
Understanding the Specs
Replacement components must match the physical space and electrical needs of the unit. The specifications for part number 5018035 include exact measurements and operating frequencies.
Be sure to check these details against your old unit before installing a new part:
- Frequency: 50/60HZ
- Height: 3.05 in / 7.75 cm
- Length: 3.9 in / 9.91 cm
- Width: 6 in / 15.24 cm
How to Tell When a Pump Has Failed
A failed pump often makes unusual humming, buzzing, or grinding sounds without actually moving any fluid. In other cases, the motor may remain completely silent and fail to start when power is supplied.
Leaks around the pump housing or fittings can also indicate physical wear or cracked internal parts. If water remains in the system when it should be clearing out, the pump may have failed.
Safe Replacement Steps
Swapping out a pump involves handling both electrical wiring and liquid lines. Follow these steps to handle the job safely:
- Shut off power at the breaker and shut off the water supply.
- Use a reliable meter to test the connections and confirm no electrical power remains.
- Take a clear photo of every wire and hose connection before disconnecting anything.
- Loosen the mounting brackets and carefully remove the old pump from the cabinet.
- Position the replacement pump into the bracket, securing all mounting hardware.
- Move wires one at a time to the same spots as shown in your photo, then reconnect all fluid lines tightly.
Read your old part
- Find the manufacturer label or stamped metal plate on your existing pump.
- Read the part number printed on the housing to verify it shows 5018035.
- Check the frequency rating to confirm it matches 50/60HZ.
- Measure the old pump to see that its dimensions align with 3.05 in height, 3.9 in length, and 6 in width.
When to call a pro
Hire a licensed technician or electrician for any step you are not sure you can do safely, or if you run into damaged wiring, complex electrical controls, or persistent leaks.
Questions
What brand makes part number 5018035?
This pump is listed under the Cleveland brand name. Always verify the part number on your existing unit to confirm compatibility.
What are the exact dimensions of this pump?
The Cleveland 5018035 measures 3.05 in / 7.75 cm in height, 3.9 in / 9.91 cm in length, and 6 in / 15.24 cm in width. Checking these measurements ensures it will fit inside your machine.
What frequency does the Cleveland 5018035 pump support?
The pump is rated for 50/60HZ operation. Check your equipment label to ensure the electrical supply matches.
How can I avoid wiring mistakes during installation?
Take a photo of every wire before removing the old part. Move the wires one at a time to the exact same terminals on the new pump.
Related part numbers
- 113231Pump, ClevelandSame brand and type
- 9161076-02Ice Machine Pump, Ice-O-MaticSame part type
- 4040144Oscillating Water Pump, AntunesSame part type
- 5030623Lamp/Bulb with Seal Reference, ClevelandSame brand
- 5018023Auxiliary Fan, ClevelandSame brand
- 9161079-03Ice Machine Pump, Ice-O-MaticSame part type
- 2062336-02SIce Machine Pump Reference, Ice-O-MaticSame part type
- 5030677Motor, ClevelandSame brand
Browse: Cleveland part numbers · Drain pumps by part number
Washer parts · All part numbers · Superseded part number lookup · How to find a replacement part · Part finder
Brand names and part numbers identify the part and show fit. FindPart is not affiliated with, authorized by, or endorsed by any equipment maker. If you are not sure a repair is safe for you, call a licensed technician.