PART NUMBER / BEVERAGE AIR

302-993ABeverage Air 302-993A Start Capacitor

Stock
Out of stock
Part type
Start capacitor

This part is out of stock right now, so it cannot be added to the cart.

One email when it is back in stock. Nothing else. Privacy policy
Add to quote list

The Beverage Air 302-993A is a start capacitor used on refrigeration appliances. It provides extra electrical power to help the compressor start up quickly and smoothly when a cooling cycle begins.

Start capacitors are designed for momentary operation during startup. They are not run capacitors. If your unit struggles to start or hums without running, checking this component is a common step.

Turn off power at the main breaker before opening any access panels, and test for power before touching any wires. A capacitor can hold an electrical charge even with the power turned off. You must discharge it safely using an insulated tool across the terminals before touching it. Never bypass any safety switches or control devices while working on your appliance.

Specifications

Part number302-993A
BrandBeverage Air
Part typeStart capacitor
Height1.95 in / 4.95 cm
Length4.25 in / 10.80 cm
Voltage110V
Width3.7 in / 9.40 cm

From the maker's and parts sellers' listings for this number. Compare with the label on your old part.

What a Start Capacitor Does

A start capacitor gives the motor a boost of torque right as it powers on. Once the motor reaches its normal running speed, the start capacitor cuts out of the circuit.

A start capacitor shows a range of microfarads (written as µF, MFD, or uF). It is used to get heavy loads moving and is not designed to stay continuously connected during the run cycle.

Understanding the 302-993A Specifications

When you check the label on your old part, verify that the physical dimensions and electrical ratings match the space in your equipment.

  • Part Number: 302-993A
  • Voltage: 110V
  • Height: 1.95 in / 4.95 cm
  • Length: 4.25 in / 10.80 cm
  • Width: 3.7 in / 9.40 cm

How to Confirm a Match

To ensure you have the correct replacement, look directly at the old part and your appliance data plate.

Match the part number on the old part, or the appliance model it is listed for. Microfarad ratings must match the old part. Voltage ratings must be the same or higher than the old capacitor, but never lower. Check the dimensions to ensure the replacement fits inside the mounting bracket.

Signs of Failure and Replacement Steps

A failing capacitor may bulge, leak, or fail to assist the motor. A motor that hums but will not spin is often a bad capacitor, not a bad motor. Follow these steps to replace it safely.

  1. Shut off power to the unit at the circuit breaker and test for power to confirm the unit is dead.
  2. Discharge the old capacitor using an insulated tool across the terminals before touching it.
  3. Take a photo of every wire before removing the old part.
  4. Remove the mounting bracket or strap holding the capacitor in place.
  5. Move wires one at a time to the same spots on the new part.
  6. Secure the new part in the bracket, close the panels, and restore electrical power.

Read your old part

  1. Locate the label on your existing capacitor.
  2. Check that the part number matches 302-993A.
  3. Verify the voltage rating says 110V.
  4. Measure the old part to confirm it matches the 1.95 in / 4.95 cm height, 4.25 in / 10.80 cm length, and 3.7 in / 9.40 cm width.
  5. Confirm the microfarad rating matches the requirement on your original part's label.

When to call a pro

Hire a licensed HVAC technician or electrician for any step you are not sure you can do safely, or if line voltage wiring is damaged.

Questions

Can a start capacitor stay in the circuit while the unit runs?

No. A start capacitor is used only to help start the motor and is not a run capacitor. It drops out of the circuit once the motor gets up to speed.

Can I replace a 110V capacitor with one that has a lower voltage rating?

No. Volts must be the same or higher. Using a capacitor with a lower voltage rating than the original is unsafe and can damage the unit.

Why does my fan or motor hum without spinning?

A fan or motor that hums but will not spin is often caused by a bad capacitor rather than a bad motor. Testing or replacing the capacitor is a standard troubleshooting step.

Why should I take a photo of the wiring before replacing the part?

Taking a photo ensures you have a clear reference for where every wire connects. You can then move wires one at a time to the exact same spots on the replacement.

Related part numbers

  • 302-628AStart Capacitor, Beverage AirSame brand and type
  • 11962Refrigerator Capacitor, MarsSame part type
  • 312-147DCompressor, Beverage AirSame brand
  • 302-828BComprssr, Beverage AirSame brand
  • 369192Capacitor, LincolnSame part type
  • 3-2-03-04-001-2Capacitor, Spaceman USASame part type
  • 312-148DCompressor, Beverage AirSame brand
  • 3-1-02-22-009Run Capacitor, Spaceman USASame part type

Browse: Beverage Air part numbers · Run and start capacitors by part number

Refrigerator parts and water filters · All part numbers · Superseded part number lookup · How to find a replacement part · Part finder

Brand names and part numbers identify the part and show fit. FindPart is not affiliated with, authorized by, or endorsed by any equipment maker. If you are not sure a repair is safe for you, call a licensed technician.