PART NUMBER / MARS
11962Mars 11962 Refrigerator Capacitor
This part is out of stock right now, so it cannot be added to the cart.
The Mars 11962 is a refrigerator capacitor designed to support electric motors during startup. It provides the extra electrical boost required to get a motor spinning from a complete stop.
If you are holding an old part stamped with 11962, this reference helps you understand its printed ratings, confirm your match, and plan a safe repair.
Turn off power at the main breaker and test for power before touching any electrical components. A capacitor can hold a charge even with the power off. It must be discharged with an insulated tool before anyone touches its terminals. Take a photo of every wire before removing a part, then move wires one at a time to the same spots on the new part.
Specifications
| Part number | 11962 |
|---|---|
| Brand | Mars |
| Part type | Refrigerator start capacitor |
| Capacitance | 88–108 MFD (µF) |
| Diameter | 1.44 " |
| Height | 3.38 " |
| Length | 1.44 " |
| Material | Plastic |
| Voltage | 330V |
| Width | 1.44 " |
From the maker's and parts sellers' listings for this number. Compare with the label on your old part.
What a Start Capacitor Does
A start capacitor provides momentary electrical assistance to help a compressor or motor start up under load. It gives a quick burst of energy and drops out of the circuit once the motor gets up to speed.
A start capacitor shows a range, like 88 to 108 uF. It is used in hard start kits and is not a run capacitor. A run capacitor stays in the circuit full time, while a start capacitor only acts during the initial seconds of starting.
Understanding the 11962 Specifications
Every capacitor lists electrical limits and physical measurements. Match these values carefully to ensure the replacement works properly and fits inside the mounting location.
- Capacitance: 88 to 108 MFD (uF)
- Voltage: 330V
- Material: Plastic
- Height: 3.38 "
- Diameter: 1.44 "
- Length: 1.44 "
- Width: 1.44 "
Signs of Failure and Safe Replacement
When a start capacitor fails, the connected motor may struggle to turn on. You might hear a hum or click as the motor tries to start but fails to spin. While a fan that hums but will not spin is often a bad capacitor, not a bad motor, the same electrical behavior can happen with other equipment motors.
Always disconnect power completely before opening any service panel. Remember that round and oval capacitors with the same ratings do the same job, so pick the shape that fits the bracket. Work slowly and handle terminals carefully.
- Shut off the power at the circuit breaker and verify the circuit is dead with a reliable tester.
- Locate the capacitor and safely discharge its terminals using an insulated tool.
- Take a clear photo of the wiring layout to document each connection point.
- Disconnect the wires and remove the old unit from its mounting clamp or bracket.
- Set the replacement unit in place and reconnect each wire to the correct terminal.
Read your old part
- Look directly at the label on your existing part to locate the printed part number.
- Confirm the label clearly reads 11962.
- Check that the capacitance rating matches the required 88 to 108 MFD (uF) range.
- Ensure the voltage rating is 330V or that your replacement meets or exceeds the required voltage.
- Match the part number on the old part, or the appliance model it is listed for.
When to call a pro
Hire a licensed HVAC technician for any step you are not sure you can do safely. If you are uncomfortable discharging high-voltage components or testing live circuits, stop immediately and contact a qualified professional.
Questions
Can I replace a start capacitor with a run capacitor?
No, a start capacitor is not a run capacitor. A start capacitor shows a capacitance range and is designed only for brief startup assistance. A dual run or single run capacitor is built to remain energized continuously.
Can I use a capacitor with a higher voltage rating?
Yes, capacitor volts must be the same or higher. For example, a 440 V capacitor can replace a 370 V one, but never the other way around. The microfarad rating, however, must match the required specification.
Why does the capacitance show a range instead of a single number?
A start capacitor shows a range, like 88 to 108 uF, because start circuits allow for a wider tolerance during brief motor starting. Run capacitors list a fixed value or a dual rating for two separate motors.
Does the outer shape of the capacitor affect its operation?
Round and oval capacitors with the same ratings do the same job. You simply need to pick the shape and size that fits securely inside your unit's mounting bracket.
Related part numbers
- 369192Capacitor, LincolnSame part type
- 302-993AStart Capacitor, Beverage AirSame part type
- 3-1-02-22-009Run Capacitor, Spaceman USASame part type
- 302-628AStart Capacitor, Beverage AirSame part type
- 3-1-02-22-061Start Capacitor, Spaceman USASame part type
- 3-2-03-04-001-2Capacitor, Spaceman USASame part type
Browse: Run and start capacitors by part number
Refrigerator parts and water filters · All part numbers · Superseded part number lookup · How to find a replacement part · Part finder
Brand names and part numbers identify the part and show fit. FindPart is not affiliated with, authorized by, or endorsed by any equipment maker. If you are not sure a repair is safe for you, call a licensed technician.