PART NUMBER / CLEVELAND

4030609Cleveland 4030609 Contactor Reference Guide

Stock
Out of stock
Part type
Contactor

This part is out of stock right now, so it cannot be added to the cart.

One email when it is back in stock. Nothing else. Privacy policy
Add to quote list

The Cleveland 4030609 is an electrical contactor used as an appliance part. It acts as an electrically controlled switch that opens and closes high-power circuits.

When a low-voltage control signal reaches the contactor coil, internal contacts close to send electrical power to heavy-draw components. Once the call stops, the contacts open to shut off power.

Turn off the electrical power at the breaker before touching any wiring, and test for power to confirm the circuit is dead. If the equipment uses an outdoor disconnect, pull that disconnect in addition to switching off the breaker. Take a photo of every wire before removing the old part so you can reconnect each wire to the exact same terminal.

Specifications

Part number4030609
BrandCleveland
Part typeContactor
Amps32 Amp
Height3.15 in / 8.00 cm
Length7.35 in / 18.67 cm
Poles3 Pole
Wattage11kw
Width6.35 in / 16.13 cm

From the maker's and parts sellers' listings for this number. Compare with the label on your old part.

What the Contactor Does

A contactor operates like a heavy-duty relay. Most contactor coils respond to a low-voltage control signal, often 24 V from a control board or transformer.

When energized, the coil creates a magnetic field that pulls the contacts together. This allows line voltage to flow through the unit. If the contacts burn, pit, or fail to move, the equipment will not run properly.

Cleveland 4030609 Specifications

Every electrical part has specific ratings that must match the load requirements of the machine. The Cleveland 4030609 carries the following measurements and ratings:

  • Poles: 3 Pole
  • Current rating: 32 Amp
  • Power rating: 11kw
  • Length: 7.35 in / 18.67 cm
  • Width: 6.35 in / 16.13 cm
  • Height: 3.15 in / 8.00 cm

How to Confirm a Match

Using the wrong contactor can cause electrical failure or prevent equipment from working. Always confirm the part number matches the stamped label on your existing component.

Match the part number on the old part, or the appliance model it is listed for. Look directly at the manufacturer tag on the body of the old switch to confirm the numbers and ratings match.

Signs of Failure and Safe Replacement

Contactors can wear out over time due to repeated electrical arcing. Physical signs of failure include blackened, pitted, or welded contacts. A broken coil will fail to pull the contacts in, leaving the circuit open.

Follow these steps to replace the part safely once you have verified the circuit is completely de-energized:

  1. Shut off power at the main breaker and any nearby disconnect switch.
  2. Use a meter to test for power at the contactor terminals to ensure no voltage is present.
  3. Take a clear photo of the existing wiring setup from multiple angles.
  4. Unfasten the old contactor from its mounting plate or rail.
  5. Move wires one at a time to the same spots on the new part, securing each terminal firmly.

Read your old part

  1. Locate the printed sticker or stamped metal tag on the body of your old contactor.
  2. Check that the part number reads 4030609.
  3. Confirm the electrical ratings match 3 Pole, 32 Amp, and 11kw.
  4. Measure the old part to make sure its physical footprint fits within 7.35 in length, 6.35 in width, and 3.15 in height.
  5. Match the part number on the old part, or the appliance model it is listed for.

When to call a pro

Line voltage electrical work carries a serious risk of shock or injury. If you cannot confirm power is off, see damaged wiring, or are not sure you can complete the repair safely, hire a licensed technician.

Questions

What do the poles on the Cleveland 4030609 mean?

The 4030609 is a 3 Pole contactor. This means it controls three separate sets of electrical contacts simultaneously when the internal coil is energized.

What are the dimensions of the Cleveland 4030609?

The dimensions are 7.35 in / 18.67 cm in length, 6.35 in / 16.13 cm in width, and 3.15 in / 8.00 cm in height. Check your mounting space to ensure proper fit.

What voltage signals commonly trigger contactor coils?

Most home thermostats, contactor coils and control boards use a 24 V control signal from a transformer. This small signal switches the higher voltage across the contactor poles.

How should I handle the wires during replacement?

Take a photo of every wire before removing the old part. Move wires one at a time to the same spots on the new part to prevent wiring errors.

Related part numbers

  • 4030610Contactor Reference, ClevelandSame brand and type
  • KE603902-6Contactor Reference Guide, ClevelandSame brand and type
  • 369479-ASMercury Contactor Reference Guide, LincolnSame part type
  • 1057841Range Igniter, ClevelandSame brand
  • 4050235Contactor, AntunesSame part type
  • 369302Mercury Contactor, LincolnSame part type
  • 5001059Solenoid Valve, ClevelandSame brand
  • 300888Timer Reference Guide, ClevelandSame brand

Browse: Cleveland part numbers · Contactors by part number · Cleveland contactors by part number

Refrigerator parts and water filters · All part numbers · Superseded part number lookup · How to find a replacement part · Part finder

Brand names and part numbers identify the part and show fit. FindPart is not affiliated with, authorized by, or endorsed by any equipment maker. If you are not sure a repair is safe for you, call a licensed technician.