PART NUMBER / LINCOLN

369479-ASLincoln 369479-AS Mercury Contactor Reference Guide

Stock
Out of stock
Part type
Mercury contactor

This part is out of stock right now, so it cannot be added to the cart.

One email when it is back in stock. Nothing else. Privacy policy
Add to quote list

The Lincoln 369479-AS is a mercury contactor. In electrical equipment, a contactor acts as a heavy-duty switch that controls electrical power to major components.

When the system calls for heating or operation, a low-voltage control signal energizes the contactor coil. This closes the internal contacts and allows higher electrical current to reach the operating circuits.

A contactor carries high voltage that can kill. Turn off the breaker and pull the outdoor disconnect, then test for power before touching anything. Take a photo of every wire before removing a part. Move wires one at a time to the same spots on the new part. Hire a licensed HVAC technician for any step you are not sure you can do safely.

Specifications

Part number369479-AS
BrandLincoln
Part typeMercury contactor
Height7.9 in / 20.07 cm
Length8.3 in / 21.08 cm
Poles3 Pole
Width13.6 in / 34.54 cm

From the maker's and parts sellers' listings for this number. Compare with the label on your old part.

Match these numbers

  1. 01Poles: same count, 1 or 2
  2. 02Coil volts: must be the same, most homes use 24 V
  3. 03Amps: same or higher than your old one

What the Contactor Does

A contactor functions as a bridge between low-voltage controls and high-power components. Most control circuits rely on a lower voltage signal to manage operation without exposing the thermostat or control board to line-level power.

When that control signal reaches the contactor coil, it moves the internal switch mechanism. In a mercury contactor, liquid mercury shifts to open or close the electrical pathways cleanly. Once engaged, full operating power flows smoothly across all connected circuits.

Understanding the Specs

Replacing an electrical contactor requires matching the physical dimensions and internal configuration precisely. The specs for part number 369479-AS include:

Physical size matters because the component must fit securely inside the control enclosure without pressing against other parts or stretching wire runs. The pole count defines how many independent circuits the contactor opens and closes at the same time.

  • Poles: 3 Pole
  • Height: 7.9 in / 20.07 cm
  • Length: 8.3 in / 21.08 cm
  • Width: 13.6 in / 34.54 cm

Signs of Failure and Safe Replacement

Contactors can wear out over years of normal operation. When a contactor fails, the equipment may not power on, or it may fail to shut off when the control cycle ends. A humming or buzzing sound without normal operation can also indicate that the coil is struggling to engage.

Follow safe replacement procedures whenever you service high-voltage electrical components:

  1. Shut off electrical power at the main breaker and disconnect, then test all lines with a meter to verify that zero power is present.
  2. Take clear photos of the wiring connections before unscrewing any terminal screws.
  3. Unfasten the mounting hardware to free the old contactor from its panel.
  4. Mount the replacement securely in place using the original bracket locations.
  5. Move each wire one at a time to the matching terminal on the new unit.
  6. Restore power only after double-checking every connection and replacing all safety covers.

Read your old part

  1. Locate the identification label on the body of your current contactor.
  2. Check that the printed part number reads exactly 369479-AS.
  3. Verify the physical measurements: height of 7.9 in / 20.07 cm, length of 8.3 in / 21.08 cm, and width of 13.6 in / 34.54 cm.
  4. Confirm the part is a 3 Pole configuration to match your system wiring.
  5. Match the part number on the old part, or the appliance model it is listed for.

When to call a pro

Hire a licensed HVAC technician for any step you are not sure you can do safely. High-voltage wiring can cause severe shock or death. If you are uncomfortable testing for live power or handling complex wiring, stop and call a professional.

Questions

What control voltage operates contactor coils?

Most home thermostats, contactor coils and control boards use a 24 V control signal from a transformer. This low-voltage signal triggers the coil to close the high-voltage contacts.

How many poles does the Lincoln 369479-AS contactor have?

The Lincoln 369479-AS is a 3 Pole contactor. This means it has three separate sets of electrical contacts that open and close simultaneously.

What are the exact dimensions of this contactor?

This part measures 7.9 in / 20.07 cm in height, 8.3 in / 21.08 cm in length, and 13.6 in / 34.54 cm in width. Always verify these dimensions against your existing cabinet space.

How should I keep track of the wiring during a replacement?

Take a photo of every wire before removing a part. Move wires one at a time to the same spots on the new part to prevent wiring errors.

Related part numbers

  • 369302Mercury Contactor, LincolnSame brand and type
  • 4030609Contactor Reference Guide, ClevelandSame part type
  • 369485Blower Motor, LincolnSame brand
  • 369422Range Relay, LincolnSame brand
  • 4030610Contactor Reference, ClevelandSame part type
  • 22540Contactor, UltrafryerSame part type
  • 369506Thermostat Parts Guide, LincolnSame brand
  • 369419Heating Element, LincolnSame brand

Browse: Lincoln part numbers · Contactors by part number

AC condenser parts · All part numbers · Superseded part number lookup · How to find a replacement part · Part finder

Brand names and part numbers identify the part and show fit. FindPart is not affiliated with, authorized by, or endorsed by any equipment maker. If you are not sure a repair is safe for you, call a licensed technician.