PART NUMBER / CLEVELAND
6016023Cleveland 6016023 Auto-Ignition Control
This part is out of stock right now, so it cannot be added to the cart.
The Cleveland 6016023 is an auto-ignition control board designed for gas burner equipment. It manages the electrical sequence needed to start and monitor the burner flame safely.
When your equipment calls for heat, this control module coordinates the spark or igniter and works with safety sensors. If it detects a fault, it stops the ignition cycle to protect the system.
Turn off power at the breaker before inspecting or touching electrical components, and test for power before proceeding. If you smell gas, do not touch any switch. Leave the house and call your gas company from outside. Never bypass a flame sensor, pressure switch, limit switch, rollout switch or float switch, as these are critical safety devices.
Specifications
| Part number | 6016023 |
|---|---|
| Brand | Cleveland |
| Part type | Auto-ignition control |
| Height | 2.5 in / 6.35 cm |
| Length | 4.5 in / 11.43 cm |
| Voltage | 110V |
| Width | 4.56 in / 11.58 cm |
From the maker's and parts sellers' listings for this number. Compare with the label on your old part.
Match these numbers
- 01Part number: listed as a replacement for yours
- 02Ignition type: same as your furnace
- 03Wiring: photo every wire first
How the Auto-Ignition Control Works
An auto-ignition control serves as the brain for the burner assembly. Once a call for heat begins, the board sends power to ignite the fuel and monitors the flame through a sensor circuit.
If the flame does not establish properly or drops out, the module cuts the signal to the gas valve. This prevents unburned fuel from collecting inside the appliance.
Understanding the Part Specifications
Replacing an electronic ignition control requires verifying both electrical requirements and the physical space inside the cabinet. The Cleveland 6016023 has specific physical dimensions and operating voltage listed in its equipment data:
- Voltage: 110V
- Height: 2.5 in / 6.35 cm
- Length: 4.5 in / 11.43 cm
- Width: 4.56 in / 11.58 cm
Signs of Failure and Safe Replacement
When an ignition module fails, the burner may not attempt to light at all, or it may stop halfway through its sequence. Burn marks, cracked circuit boards, or loose terminal pins also point to a damaged control.
Always shut down electrical power and test for power before touching any wires. Follow these general steps when handling a replacement control board:
- Turn off the electrical breaker powering the unit and verify that all power is disconnected.
- Take a clear photo of every wire connected to the old board to preserve the layout.
- Remove the mounting hardware holding the module in place.
- Move wires one at a time to the matching spots on the replacement unit.
- Secure the control board back into its bracket before restoring power.
Read your old part
- Turn off power to the unit and remove the service panel to access the existing control board.
- Locate the printed label or stamped marking on the face of the old module.
- Look for part number 6016023 directly on the module.
- Check the voltage rating on the label to verify it specifies 110V.
- Measure the old module to ensure its dimensions match 2.5 in / 6.35 cm height, 4.5 in / 11.43 cm length, and 4.56 in / 11.58 cm width.
When to call a pro
Hire a licensed HVAC technician for any step you are not sure you can do safely. Gas valve work means opening gas lines and setting gas pressure, which a licensed tech should do.
Questions
What voltage does the Cleveland 6016023 require?
This control board operates on 110V. Always verify your equipment power matches this rating before connecting wires.
What should I do if I smell gas while checking the board?
If you smell gas, do not touch any switch. Leave the house immediately and call your gas company from outside.
Can I bypass a safety switch to test if this control board is bad?
No. Never bypass a flame sensor, pressure switch, limit switch, rollout switch or float switch. They are safety devices designed to prevent damage and hazards.
How can I avoid wiring mistakes during replacement?
Take a photo of every wire before removing the old part. Move the wires one at a time to the same spots on the new part.
Related part numbers
Browse: Cleveland part numbers
Furnace parts · All part numbers · Superseded part number lookup · How to find a replacement part · Part finder
Brand names and part numbers identify the part and show fit. FindPart is not affiliated with, authorized by, or endorsed by any equipment maker. If you are not sure a repair is safe for you, call a licensed technician.