The Cleveland KE51688 is a power jack/actuator complete assembly. It provides motorized movement to raise, lower, or tilt components inside compatible commercial equipment.

When the equipment control calls for motion, this motorized actuator drives the mechanical lift assembly. Replacing a worn unit restores smooth, steady physical movement.

Turn off the power at the circuit breaker and test for power before touching any wiring or opening panels. Support any raised or heavy mechanical parts securely so they cannot drop while the actuator is detached. Take a photo of all electrical connections before disconnecting anything so wires return to the correct terminals.

Specifications

Part numberKE51688
BrandCleveland
Part typePower jack/actuator complete
Height3.6 in / 9.14 cm
Length9.5 in / 24.13 cm
Voltage115V
Width14.45 in / 36.70 cm

From the maker's and parts sellers' listings for this number. Compare with the label on your old part.

What the Power Jack Actuator Does

An actuator converts electrical power into controlled physical motion. In commercial food service equipment, an actuator complete assembly tilts or lifts heavy components smoothly.

Internal gears and a drive mechanism handle the load. When the drive motor receives a signal from the controls, it moves the jack mechanism forward or backward to position the equipment.

Understanding the KE51688 Specifications

Using the exact physical dimensions and electrical rating is critical for proper operation and fit inside the equipment housing.

  • Voltage: 115V
  • Height: 3.6 in / 9.14 cm
  • Length: 9.5 in / 24.13 cm
  • Width: 14.45 in / 36.70 cm

Confirming the Correct Replacement Part

To ensure this part fits your appliance, check the manufacturer label on the old component. Match the part number on the old part, or the appliance model it is listed for.

Verify that your system supply voltage matches the 115V rating on the actuator label. The mounting points and overall dimensions must also match the original unit to align with existing hardware.

Signs of Failure and Replacement Steps

Actuators can fail mechanically or electrically. You may hear humming without movement, grinding sounds, or the unit may stop moving completely when switched on.

Follow these basic steps when swapping out an old actuator assembly:

  1. Shut off electrical power to the machine at the circuit breaker and verify the power is off.
  2. Brace or mechanically support the assembly that the actuator normally holds.
  3. Photograph all wire connections, then disconnect the wiring harness.
  4. Remove the mounting pins or bolts holding the old actuator in place.
  5. Position the replacement actuator, secure the mounting hardware, and reconnect the wires to their matching terminals.

Read your old part

  1. Locate the identification tag or stamped label on your existing actuator assembly.
  2. Wipe away dust or grease to clearly read the stamped manufacturer and model markings.
  3. Verify that the number reads KE51688.
  4. Confirm the electrical rating on your old part specifies 115V.
  5. Measure the old unit to verify the height is 3.6 in / 9.14 cm, length is 9.5 in / 24.13 cm, and width is 14.45 in / 36.70 cm.

When to call a pro

Hire a licensed technician or electrician for any step you are not sure you can do safely, or if you suspect electrical supply issues beyond the actuator.

Questions

What voltage does the Cleveland KE51688 operate on?

The Cleveland KE51688 power jack actuator complete is rated for 115V. Always verify your equipment power matches this rating before installation.

What are the dimensions of this actuator assembly?

The assembly measures 3.6 in / 9.14 cm in height, 9.5 in / 24.13 cm in length, and 14.45 in / 36.70 cm in width. These dimensions help confirm it fits within the equipment housing.

How do I make sure the wires go back in the right spots?

Take a photo of every wire before removing the old part. Move the wires one at a time to the same spots on the new part.

Related part numbers

  • KE52055Overload Heater, ClevelandSame brand and type
  • KE50581Bridge Rectifier, ClevelandSame brand and type
  • KE50753-10Relay, ClevelandSame brand
  • R35-EWP0961A-115VTemperature Controller, Desmon USASame part type
  • KE02097-1Wire Harness, ClevelandSame part type
  • KE53838-10Transformer, ClevelandSame brand
  • KE50753-7Omron Relay, ClevelandSame brand
  • RTP00083Electronic Ballast, DelfieldSame part type

Browse: Cleveland part numbers

Refrigerator parts and water filters · All part numbers · Superseded part number lookup · How to find a replacement part · Part finder

Brand names and part numbers identify the part and show fit. FindPart is not affiliated with, authorized by, or endorsed by any equipment maker. If you are not sure a repair is safe for you, call a licensed technician.