The Cleveland KE52055 is an overload heater designed for commercial appliance controls. It acts as a thermal sensing element inside a motor starter or overload relay. As electric current flows through the circuit, the heater monitors operating heat levels to safeguard motors from sustained electrical overloads.

When excessive current passes through the equipment, the heater warms up and triggers the overload switch to trip. This shuts down power to the motor before extreme heat causes permanent damage to the internal motor windings.

Turn off power at the breaker before opening any appliance control panel, and test for power with a meter before touching any wiring. Take a clear photo of the wiring and terminal connections before removing any part so everything goes back to its original position. Never attempt to bypass an overload safety control or install an incorrect heater size to clear an electrical trip.

Specifications

Part numberKE52055
BrandCleveland
Part typeOverload heater
Height0.45 in / 1.14 cm
Length1.9 in / 4.83 cm
Voltage208-415V
Width0.45 in / 1.14 cm

From the maker's and parts sellers' listings for this number. Compare with the label on your old part.

What the Overload Heater Does

An overload heater is a critical protective component in electric motor circuits. Unlike standard fuses or circuit breakers that trip instantly during a direct short circuit, an overload heater responds to gradual heat buildup caused by heavy mechanical loads or fluctuating voltage.

The heater sits directly in the motor's power path within the overload relay block. If the motor draws more current than normal over a set period, the thermal element bends or melts a solder link, releasing the spring-loaded contacts. This cuts the control circuit and stops the motor safely.

Cleveland KE52055 Specifications

Replacing an overload heater requires exact physical dimensions and proper electrical ratings so it fits the relay block securely and reacts at the right temperature.

The Cleveland KE52055 features the following exact specifications:

  • Voltage: 208-415V
  • Length: 1.9 in / 4.83 cm
  • Width: 0.45 in / 1.14 cm
  • Height: 0.45 in / 1.14 cm

Confirming the Correct Part Number

Heaters look very similar to one another across different amp ratings. Installing a heater with the wrong thermal rating can cause nuisance trips or leave the motor without proper protection. To ensure safe operation, verify the part number on the old component matches KE52055 exactly.

Always match the part number stamped on the old part or verify it against the appliance model it is listed for. Because this part does not have alternate replacement part numbers listed, matching the exact number ensures correct thermal calibration.

Signs of Failure and Replacement Steps

Overload heaters can burn open after severe electrical faults, or they may fail to hold circuit continuity after years of thermal cycling. If a motor refuses to run, the relay will not reset, or you see visible discoloration, the heater may need replacement.

  1. Shut off electrical power to the appliance at the main breaker panel and verify the circuit is completely dead using a multimeter.
  2. Open the control cabinet and locate the motor starter relay where the overload heater is installed.
  3. Take a photo of the wire placement and mounting screws before loosening any hardware.
  4. Carefully remove the mounting screws holding the old heater in the relay block and lift it out.
  5. Position the new KE52055 heater into the mounting slots and tighten the screws firmly to ensure good electrical contact.
  6. Restore electrical power at the breaker panel and test the appliance to confirm normal motor operation.

Read your old part

  1. Turn off all power to the equipment and access the motor starter relay inside the control box.
  2. Clean away any surface dust to expose the printed or stamped markings on the old heater.
  3. Confirm the stamped number reads KE52055.
  4. Check the operating voltage of your equipment circuit to confirm it falls within the 208-415V range.
  5. Measure the old part to confirm it matches the 1.9 in / 4.83 cm length and 0.45 in / 1.14 cm width and height.

When to call a pro

If the motor continues to trip the overload relay immediately after installation, or if you are uncomfortable testing high-voltage commercial electrical circuits, stop work and hire a licensed professional.

Questions

What voltage is the Cleveland KE52055 rated for?

The Cleveland KE52055 is rated for 208-415V circuits. Always verify that your equipment power supply matches this rating before installation.

What are the dimensions of the KE52055 overload heater?

This part measures 1.9 in / 4.83 cm in length, 0.45 in / 1.14 cm in width, and 0.45 in / 1.14 cm in height. These dimensions allow it to seat securely in compatible overload relay blocks.

Can I replace the KE52055 with a different heater number?

No other replacement part numbers are listed for the KE52055. Because overload heaters are calibrated to specific current levels, you should only install the exact specified part number.

Related part numbers

  • SK2346101Actuator Reference Guide, ClevelandSame brand and type
  • KE51688Power Jack/Actuator Complete, ClevelandSame brand and type
  • R35-EWP0961A-115VTemperature Controller, Desmon USASame part type
  • KE53838-10Transformer, ClevelandSame brand
  • RTP00083Electronic Ballast, DelfieldSame part type
  • KE50581Bridge Rectifier, ClevelandSame part type
  • KE53838-12Transformer, ClevelandSame brand
  • KE50753-10Relay, ClevelandSame brand

Browse: Cleveland part numbers

Refrigerator parts and water filters · All part numbers · Superseded part number lookup · How to find a replacement part · Part finder

Brand names and part numbers identify the part and show fit. FindPart is not affiliated with, authorized by, or endorsed by any equipment maker. If you are not sure a repair is safe for you, call a licensed technician.