PART NUMBER / CLEVELAND
KE603902-5Cleveland KE603902-5 Contactor
This part is out of stock right now, so it cannot be added to the cart.
The Cleveland KE603902-5 is an electrical contactor. It acts as an electrically controlled switch that opens and closes high-voltage circuits to supply power to internal equipment components.
When a lower control voltage reaches the contactor coil, it pulls internal contacts together. This allows main line voltage to pass through the terminal poles and run the heavy electrical loads in your unit.
A contactor carries high voltage that can kill. Turn off power at the main breaker, pull any outdoor disconnect, and always test for power before touching any wires or terminals. Take a clear photo of every wire before removing an old contactor. Move wires one at a time to the matching spots on the replacement part. Hire a licensed technician or electrician for any step you are not sure you can do safely.
Specifications
| Part number | KE603902-5 |
|---|---|
| Brand | Cleveland |
| Part type | Contactor |
| Amps | 50A |
| Height | 2.1 in / 5.33 cm |
| Length | 5.05 in / 12.83 cm |
| Poles | 3 Pole |
| Voltage | 208/240V |
| Width | 3.55 in / 9.02 cm |
From the maker's and parts sellers' listings for this number. Compare with the label on your old part.
How This Contactor Works
Contactors handle higher electrical current than standard thermostats or control boards can safely switch on their own. Most control setups use a low-voltage signal, such as a 24 V control signal from a transformer, to energize the contactor coil.
When that signal arrives, an electromagnet pulls the contact points closed. That completes the circuit and sends line power to high-draw parts. When the call for power stops, a spring pushes the contacts apart, cutting line power immediately.
Understanding the KE603902-5 Specifications
Every contactor has electrical ratings and physical dimensions that must match the circuit it protects. The ratings printed on the Cleveland KE603902-5 define how much power it safely handles.
Using a part with lower ratings can cause overheating, electrical failure, or equipment damage. Always verify the following specifications from the part label:
- Voltage: 208/240V
- Current rating: 50A
- Poles: 3 Pole
- Length: 5.05 in / 12.83 cm
- Width: 3.55 in / 9.02 cm
- Height: 2.1 in / 5.33 cm
Signs of Contactor Failure and Replacement Steps
Electrical contacts can pit, burn, or stick together over time after thousands of switching cycles. If the contacts stay stuck closed, equipment may continue to run when it should shut off. If the contacts burn or the coil fails, power will not pass through at all.
Replacing a contactor involves basic hand tools and strict electrical safety practices:
- Shut off electrical power completely at the breaker panel and any local equipment disconnect.
- Use a reliable meter to test the terminals and verify no voltage is present.
- Take a photo of all incoming line, outgoing load, and low-voltage coil wires.
- Loosen the terminal screws and label each wire if the markings are unclear.
- Unscrew the mounting hardware, set the new contactor in place, and secure it.
- Transfer the wires one at a time to the matching terminals, tightening all connections firmly.
Read your old part
- Shut off power to the unit and access the electrical control compartment.
- Locate the identification tag or printed label on the body of your existing contactor.
- Check that the part number matches KE603902-5 directly.
- Confirm the electrical ratings on the old label show 208/240V, 50A, and 3 Pole.
- Measure the mounting footprint to ensure it fits the dimensions of 5.05 in / 12.83 cm long, 3.55 in / 9.02 cm wide, and 2.1 in / 5.33 cm high.
When to call a pro
Line voltage wiring carries severe shock hazards that can cause serious injury or death. If you are uncomfortable measuring voltage, cannot verify power is off, or find burned wiring inside the cabinet, stop immediately. Contact a licensed HVAC technician or electrician to complete the repair.
Questions
What does a 3 pole contactor do?
A 3 pole contactor has three separate sets of electrical contacts that open and close at the same time. This design allows it to switch three separate power lines simultaneously.
What voltage does the KE603902-5 handle?
The Cleveland KE603902-5 is rated for 208/240V line voltage circuits. It carries a continuous current rating of 50A.
How do I know this contactor will fit my equipment?
Match the part number directly to the number on your old part, or check the appliance model documentation it is listed for. You can also compare physical dimensions and electrical ratings.
Related part numbers
- KE603902-6Contactor Reference Guide, ClevelandSame brand and type
- KE603902-4Contactor, ClevelandSame brand and type
- 3-1-01-01-010Contactor, Spaceman USASame part type
- KE603902-2Contactor, ClevelandSame part type
- SE00131Indicator Light Replacement Kit, ClevelandSame brand
- 18A100Contactor, UltrafryerSame part type
- AS-1119522Contactor, APW WyottSame part type
Browse: Cleveland part numbers · Contactors by part number · Cleveland contactors by part number
Refrigerator parts and water filters · All part numbers · Superseded part number lookup · How to find a replacement part · Part finder
Brand names and part numbers identify the part and show fit. FindPart is not affiliated with, authorized by, or endorsed by any equipment maker. If you are not sure a repair is safe for you, call a licensed technician.