PART NUMBER / SPACEMAN USA

3-1-02-22-061Spaceman USA 3-1-02-22-061 Start Capacitor

Stock
Out of stock
Part type
Start capacitor

This part is out of stock right now, so it cannot be added to the cart.

One email when it is back in stock. Nothing else. Privacy policy
Add to quote list

The 3-1-02-22-061 is a start capacitor for Spaceman USA equipment. It helps supply the quick surge of electrical energy needed to start a motor.

Start capacitors show a capacitance range and assist during startup. They are not run capacitors. Once the motor gets up to speed, the start capacitor drops out of the active circuit.

Turn off the power at the main breaker before opening any equipment panels, then test with a meter to verify power is completely off. A capacitor can hold a dangerous electrical charge even when the power is off. It must be discharged with an insulated tool before anyone touches its terminals. Take a clear photo of all wiring connections before disconnecting the old capacitor.

Specifications

Part number3-1-02-22-061
BrandSpaceman USA
Part typeStart capacitor
Frequency50/60HZ
Height2.2 in / 5.59 cm
Length7.35 in / 18.67 cm
Voltage330VAC
Width3.15 in / 8.00 cm

From the maker's and parts sellers' listings for this number. Compare with the label on your old part.

What this start capacitor does

An electric motor requires more power to begin turning than it does to keep running. A start capacitor provides that extra boost of torque at startup.

Unlike run capacitors that stay active the entire time a motor runs, start capacitors are designed only for brief duty during startup. They are used in hard start setups to help equipment start smoothly.

Understanding the specifications

Every capacitor lists electrical and physical limits on its outer casing. You must match these ratings closely to keep your equipment running properly.

  • Voltage: 330VAC. The replacement voltage must always be the same or higher than the original rating.
  • Frequency: 50/60HZ. This indicates the electrical cycle rate the part is built to handle.
  • Length: 7.35 in / 18.67 cm.
  • Width: 3.15 in / 8.00 cm.
  • Height: 2.2 in / 5.59 cm.

How to tell if a capacitor has failed

When a start capacitor fails, the connected motor may struggle to turn on. You might hear the motor hum without actually spinning.

A failing capacitor can also show physical signs. Look for a swollen or bulged casing, leaking fluid, or scorch marks around the terminals. If the casing is deformed, the part has failed and must be swapped out.

Safe replacement steps

Replacing a capacitor is straightforward if you handle electrical safety correctly.

Always move wires one by one to avoid mixing up connections.

  1. Shut off power at the breaker panel and verify there is no voltage at the unit.
  2. Safely discharge the old capacitor across its terminals using an insulated tool.
  3. Take a photo of the wire placement on the terminals for reference.
  4. Remove the mounting bracket and disconnect the wires one at a time, moving them directly to the matching spots on the replacement unit.
  5. Secure the capacitor back in its mounting bracket, close all panels, and restore power.

Read your old part

  1. Locate the part number printed on the label of your existing part.
  2. Confirm the label reads 3-1-02-22-061.
  3. Check the voltage rating to confirm it is listed as 330VAC.
  4. Check that the frequency rating matches 50/60HZ.
  5. Measure the physical space in your equipment bracket to verify the dimensions of 7.35 in / 18.67 cm length, 3.15 in / 8.00 cm width, and 2.2 in / 5.59 cm height will fit.

When to call a pro

Working with high voltage and stored electrical charges can be dangerous. Hire a licensed technician for any step you are not sure you can do safely.

Questions

What happens if a start capacitor goes bad?

A bad start capacitor usually prevents the motor from starting. A motor that hums but will not spin is often caused by a bad capacitor rather than a bad motor.

Can I use a capacitor with a higher voltage rating?

Yes. Capacitor voltage must be the same or higher than the original part. For example, a higher voltage rating can safely replace a lower one, but never the other way around.

Is a start capacitor the same as a run capacitor?

No. A start capacitor shows a microfarad range and operates only during the initial seconds of motor startup. It is used in hard start kits and is not a run capacitor.

Why do I need to discharge the capacitor before touching it?

A capacitor stores electrical energy like a battery. It can hold a strong charge even after the power breaker is turned off, so it must be discharged with an insulated tool before you touch its terminals.

Related part numbers

Browse: Spaceman USA part numbers · Run and start capacitors by part number

Refrigerator parts and water filters · All part numbers · Superseded part number lookup · How to find a replacement part · Part finder

Brand names and part numbers identify the part and show fit. FindPart is not affiliated with, authorized by, or endorsed by any equipment maker. If you are not sure a repair is safe for you, call a licensed technician.