The Lincoln 369485 is a blower motor listed under the Lincoln brand name. It is designed to drive airflow through equipment to keep air moving properly during operation.

If you are holding an old part with the number 369485, this page serves as a plain reference for its specifications, how to confirm an exact match, and how to plan for a safe replacement.

Turn off electrical power at the main breaker before touching any wiring or opening the unit cabinet. Always test for power with a reliable meter to verify the circuit is dead before servicing the motor. A capacitor can hold an electrical charge even after power is turned off. It must be discharged with an insulated tool before anyone touches the terminals.

Specifications

Part number369485
BrandLincoln
Part typeBlower motor
Frequency60HZ
Height8 in / 20.32 cm
Horsepower1/10HP
Length12 in / 30.48 cm
Voltage208/240V
Width10 in / 25.40 cm

From the maker's and parts sellers' listings for this number. Compare with the label on your old part.

What the Lincoln 369485 Blower Motor Does

A blower motor turns the blower wheel or fan blades inside an appliance or heating system. This rotation moves air across components, circulating warm or cool air as needed.

When a blower motor wears out, the airflow stops or becomes very weak. This can cause the equipment to overheat, trip internal safety controls, or fail to heat or cool properly.

Understanding the Motor Specifications

Electrical and physical ratings must match your old motor to ensure correct speed, power, and physical clearance inside the mounting compartment.

  • Voltage: 208/240V. This motor requires a high-voltage line to run and must be wired to a compatible electrical supply.
  • Frequency: 60HZ. This matches standard North American power grids.
  • Horsepower: 1/10HP. This is the mechanical power output the motor delivers to turn the blower.
  • Dimensions: Length is 12 in / 30.48 cm, width is 10 in / 25.40 cm, and height is 8 in / 20.32 cm. These dimensions ensure the motor fits within the original housing and brackets.

Signs of Motor Failure and Troubleshooting

When a blower motor fails, you may notice unusual humming noises, grinding sounds from worn bearings, or complete silence when the system calls for air.

Note that a fan that hums but will not spin is often a bad capacitor, not a bad motor. Checking external components and confirming the motor receives power can help pinpoint the issue before removing the motor.

Safe Removal and Installation Steps

Replacing an electric motor requires careful attention to wiring connections and secure mechanical mounting.

  1. Shut off power at the breaker panel and test with a meter to ensure no power is present.
  2. Take a photo of every wire before removing the old part so you have a clear reference.
  3. Carefully disconnect the electrical leads. If a capacitor is connected, discharge it safely using an insulated tool.
  4. Loosen the mounting bolts and detach the blower wheel from the motor shaft.
  5. Mount the replacement securely in the bracket, ensuring shaft alignment is straight.
  6. Move wires one at a time to the same spots on the new part, referring to your photo.
  7. Restore electrical power at the breaker and test the system for normal operation.

Read your old part

  1. Look at the metal data plate or printed label on your old blower motor.
  2. Check that the part number reads 369485.
  3. Verify the electrical specifications on the old label state 208/240V, 60HZ, and 1/10HP.
  4. Measure the old motor to confirm it matches 12 in / 30.48 cm in length, 10 in / 25.40 cm in width, and 8 in / 20.32 cm in height.
  5. Match the part number on the old part, or check the appliance model documentation to verify compatibility.

When to call a pro

Hire a licensed HVAC technician or licensed electrician for any step you are not sure you can do safely. Working with high voltage carries severe risk, and professional installation ensures your equipment runs safely.

Questions

What voltage does the Lincoln 369485 blower motor require?

The Lincoln 369485 runs on 208/240V at a frequency of 60HZ. It is intended for high-voltage power supplies.

What should I check if the blower motor hums but will not turn?

A fan that hums but will not spin is often caused by a bad capacitor rather than a failed motor. Always inspect and test the capacitor before replacing the motor itself.

How can I avoid wiring mistakes during replacement?

Take a photo of every wire before removing the old part. When installing the replacement, move wires one at a time to the same spots on the new part.

What are the physical dimensions of the 369485 motor?

This motor measures 12 in / 30.48 cm in length, 10 in / 25.40 cm in width, and 8 in / 20.32 cm in height.

Related part numbers

  • 369539Motor, LincolnSame brand and type
  • 369214Motor, LincolnSame brand and type
  • 369506Thermostat Parts Guide, LincolnSame brand
  • 369479-ASMercury Contactor Reference Guide, LincolnSame brand
  • 833697Refrigerator Condenser Fan Motor, MaytagSame part type
  • 369212Oven Fan Motor, LincolnSame part type
  • 369509Relay, LincolnSame brand
  • 369422Range Relay, LincolnSame brand

Browse: Lincoln part numbers · Appliance motors by part number · Lincoln appliance motors by part number

Refrigerator parts and water filters · All part numbers · Superseded part number lookup · How to find a replacement part · Part finder

Brand names and part numbers identify the part and show fit. FindPart is not affiliated with, authorized by, or endorsed by any equipment maker. If you are not sure a repair is safe for you, call a licensed technician.